How to count seeds from a photo
A photo seed counter gives you a number and a map of the detections. Use both to catch missed seeds, debris and double counts before you record a sample.
Set up the tray so each seed is visible
Give the working sample an ID before moving any seeds. Spread them in a single layer on a matte surface that contrasts with their color. Leave room around the edges and between seeds. If the tray is too small, pour the sample into two separate trays and label both with the parent sample ID.
Decide what belongs in the count before taking the picture. Remove obvious loose plant debris if your procedure calls for it. Record how you handled broken pieces and coated seeds so another operator can apply the same rule. For a formal seed analysis, use the working portion and counting rules prescribed by your method.
Photograph each tray from directly above
Use even light and hold the camera parallel to the tray. Check the corners and the edges of the image before submitting it. A shadow that hides a seed or a seed clipped at the edge makes the count harder to verify. In SeedMetrics, select the crop and the separated-seed counting mode. A calibration marker is only needed for measurements that require physical dimensions.
Check the detections before accepting the total
Zoom in on clusters, shadows and tray edges. A visible seed without a point may have been missed. Two points on one seed or a point on debris can inflate the count. If any region is hard to review, spread those seeds out and photograph the tray again. Keep the replacement linked to the same tray ID.
In this example, the first photo of sample S-01 shows 241 detections, including a point on a loose husk fragment. The operator removes the fragment, divides the entire sample into two trays and checks the detections against the visible seeds in each tray. Only the two accepted tray counts go into the sample total.
| Record | Disposition | Count |
|---|---|---|
| Original photo | Superseded | 241 |
| S-01-A | Accepted | 118 |
| S-01-B | Accepted | 122 |
| S-01 total | Accepted trays only | 240 |
Leave enough information to reproduce the count
Save the accepted counts and photos against the same sample ID. Mark any superseded photo in the lab record. If you need a manual check, record which tray or region was checked and what you changed after the review. For a side-by-side comparison with a mechanical seed counter, use the same working sample and reconcile differences against a reviewed reference count.
- Every seed appears in one accepted photo.
- The crop, sample ID and tray ID match the working record.
- The person reviewing the result can find the photos and the reason for any repeat.
Further reading
Check your first sample in SeedMetrics
Start with a tray you can verify by hand. Review the markers before using the result for a larger sample.